Comparison of shunt fraction estimation using transcolonic iodine-123-iodoamphetamine and technetium-99m-pertechnetate in a group of dogs with experimentally-induced chronic biliary cirrhosis.
 Portosystemic shunt fraction estimation using transcolonic iodine-123-iodoamphetamine (IMP) has been previously validated relative to portal vein macroaggregated albumin injections using an experimental model of cirrhosis.
 Transcolonic technetium-99m-pertechnetate (TcO4-) has been proposed as an alternative tracer to IMP to study portal circulation in cirrhotic patients.
 We compared shunt fraction estimates from paired transcolonic IMP and TcO4- studies performed on a group of dogs before and after common bile duct ligation surgery.
 Pertechnetate over-estimated shunt fraction in 6/7 postoperative studies relative to IMP.
 A good correlation between the two methods was demonstrated, however, the slope of the regression line was substantially less than 1.0 with TcO4- values reaching 100% at IMP shunt values of approximately 60%.
 This apparent inability to accurately assess high shunt flows may limit the quantitative aspects of TcO4- studies on patients with severe portosystemic shunting.